Who this is for. Admins and managers: the key is issued under Settings → Sensors & Predictions. Anyone who writes firmware or automations can do the posting — there is nothing to install on the device side beyond an HTTP POST.

What You Need

1

Get an ingest key

Issue it in Settings → Sensors & Predictions. It is shown once, so copy it when it appears.
2

Get an asset ID

Use the copy button beside each asset on the same settings page.
3

Have something that can POST JSON over HTTPS

That is the whole requirement.

The Endpoint

The body is a batch of readings:
  • equipment_id — the asset’s ID. Only assets in your own business are accepted.
  • metric — one of temperature_c, pressure_kpa, vibration_mm_s, runtime_hours, error_codes.
  • value — the number. unit is optional, 20 characters max.
  • recorded_at — any ISO 8601 spelling. Omit it and the server stamps the arrival time; send a time without a zone and it is read as UTC.
  • Up to 200 readings per request — batch a queue rather than posting once per sample.

Send Your First Reading

1

Open Settings → Sensors & Predictions

The Connect a device section shows the endpoint and a complete curl example.
2

Issue a key

The curl example fills in with your key the moment it is issued.
3

Run it

Swap ASSET_UUID for a copied asset ID and run the command, or paste the key into Send a test reading and press the button.
4

Confirm

The key row shows Last used the moment the endpoint accepts a batch.

Recipes

How Readings Are Used

Readings above their threshold count as fault signals in asset health scoring. Thresholds and per-metric switches live on the same settings page:
  • A metric switched off still records readings but never affects a score.
  • Switching an asset off stops its feed entirely without deleting history.
  • The sample the test button posts is runtime hours, which has no default threshold — connecting can never alarm on its own.

Common Problems

The key is wrong or revoked. Keys are stored hashed — a revoked key cannot be restored; issue a new one and update the device.
The asset ID does not belong to your business, or sensors are switched off for that asset.
The reply lists the index and field that failed — usually a typo in metric or a malformed timestamp.
They are below threshold, or the metric is switched off — both are by design.
It is plain HTTPS POST — no VPN, no mTLS. Test the same URL from a laptop with the curl example first.